3.2.3.1 General
- Alternative footprints shall be selectable when placing the schematic symbol.
- All component footprints shall have a height greater than zero.
- All label footprints shall have a default height of 0.1mm.
- Designs shall only use mechanical layers 1 to 16 with usage as follows:
- Mechanical 1 = PCB outline
- Mechanical 2 = Component location details, dimensions, PCB outline, mating PCB outline
- Mechanical 3 = Press fit drilling and via information (blind, buried, microvia etc.)
- Mechanical 4 = Countersink / counter-bore info
- Mechanical 5 = Chamfer info e.g. PCI connector, BRIC daughters
- Mechanical 6 = Thickness reduction info
- Mechanical 7 = Scoring and Flex-Rigid information
- Mechanical 8 = PCB routing and cut-out
- Mechanical 13 = 3D body
- Mechanical 15 = Courtyard info
- Component footprints shall have a 3D extrusion representation or where necessary a STEP model.
- 3D representations shall be generic.